About the Generator Size Calculator
This free browser tool helps you pick a generator size for portable or standby use. You enter each load on its own line with running watts then starting watts. Add a safety margin percentage and a generator power factor. The tool sums running watts, finds the largest extra starting surge, computes the peak at start up, applies your margin, and converts required kW to kVA using the power factor. Results update instantly as you type and there is no calculate button. You can copy results or share a link that reopens with your numbers. The page shows a safety caveat: fitting a transfer switch must be done by a licensed electrician, and never run a generator indoors or in a garage. No data leaves your browser while you use the page.
How to use it
- 1Enter each item on its own line as: running_watts then starting_watts
- 2Set a Safety margin percentage you want to apply
- 3Set a Generator power factor (for kVA conversion)
- 4Read Suggested generator size, kVA, total running watts and peak start-up
- 5Copy results or share a link that reopens with your numbers
Worked example
Inputs (one per line): Refrigerator 700 2000; Lights 400 400; Sump pump 1200 3000. Total running watts = 2,300 W. Largest extra starting surge = 1,800 W. Peak at start-up = 4,100 W. With 20% margin suggested generator size = 4,920 W. In kVA (power factor 0.8) = 6.15 kVA.
The formula
Running watts = sum of every item's running wattsLargest extra starting surge = max(starting_watts - running_watts) for any itemPeak = Running watts + Largest extra starting surgeSuggested size = Peak * (1 + Safety margin fraction)kVA = kW / power factorNote: Only one motor usually starts at a time, so peak uses just the largest extra starting surgeSource: San Diego Gas & Electric generator worksheetGenerac guidance on choosing a generator. Last checked 13 November 2026.
What it is good for
- Instant results as you type, no calculate button
- Shows total running watts, largest starting surge, peak and suggested size
- Converts required kW to kVA using your power factor and shares a link
- Does not apply site derating for altitude or temperature
- Assumes only one motor starts at a time unless you enter combined starts
Questions people ask
How do I enter loads?
Put one item per line with running watts then starting watts. Example: 800 2500 for an 800 W running load that draws 2,500 W at startup.
What if multiple motors start together?
This worksheet adds only the largest starting surge. If several motors will start at once, add their extra starts together or use a larger safety margin.
What safety margin should I use?
Common practice is 10 to 25 percent. Use 20 percent for typical uncertainty. Treat all results as estimates, not guarantees.
How is kVA calculated here?
The tool divides required kW by the generator power factor you enter. A 0.8 power factor is a common conservative default.
Can I connect this generator to my house wiring?
You must use a transfer switch fitted by a licensed electrician to connect to house wiring. Check local codes and utility rules first.
Does the tool send my data anywhere?
No. The calculator runs in your browser and updates instantly as you type. You can copy results or create a link that stores your numbers in the link.
Help keep every tool free
FreeToolr stays free because people help it grow. Share a tool you like, tell us what to build next, or support us on Ko-fi.